Exposure Limit Changes

30 Oct 2026

Gas and particle detection and protection

Workplace exposure limits are changing. Are you ready?

Review your airborne hazards, monitoring equipment and respiratory protection with Rowe Scientific.

1 December 2026
Agreed national implementation date. Check requirements with your regulator.

Official WEL transition guidance


Workplace exposure limits: what is changing?

Australia is transitioning from workplace exposure standards (WES) to workplace exposure limits (WEL). Work can release airborne dusts, gases, fumes, vapours and mists. Identify what your workplace uses or generates, then check the relevant limits and controls.

Continue to apply the current WES through 30 November 2026. The agreed WEL commencement is 1 December 2026, subject to implementation in the applicable jurisdiction. Read Safe Work Australia’s transition guidance.

Chemical not listed here? Check the full official limits.

This campaign covers selected changes. Absence from this page does not establish that a chemical is unchanged or that exposure is acceptable.

Current WES list (PDF)   |   WEL list (PDF)

Newly listed contaminants

Selected additions from the campaign are shown below. Use the complete WEL document for the applicable averaging period, chemical identity and advisory notations.

Selected additions. Source: Safe Work Australia, WEL list (November 2025).
ContaminantWEL value
Bisphenol-A2 mg/m³ TWA
Diesel particulate matter
As respirable elemental carbon
0.01 mg/m³ TWA
Flour (cereal) dust0.5 mg/m³ TWA
Peracetic acid0.4 ppm (1.24 mg/m³) peak limit
Official WEL row

Peracetic acid: Safe Work Australia evaluation report (basis for peak limitation)

Non-threshold genotoxic carcinogens

For these substances, a practical protective exposure level cannot be assigned. The WEL transition removes numerical limits for 33 identified contaminants; the requirement to eliminate or minimise risk remains. Campaign examples include acrylamide, acrylonitrile, 1,3-butadiene, ethylene oxide, hydrazine and vinyl chloride.

Source: official changes and carcinogen guidance

Selected decreases in exposure limits

Selected campaign comparisons, clarified for substance form and particle fraction. Source: Safe Work Australia comparison, pp. 6–12.
SubstanceCurrent WESWEL from 1 December 2026
Acetic anhydride5 ppm peak limitation0.5 ppm TWA
1 ppm STEL
Acetone500 ppm TWA
1,000 ppm STEL
250 ppm TWA
500 ppm STEL
Chloroform2 ppm TWA0.5 ppm TWA
Ethanol (ethyl alcohol)1,000 ppm TWA200 ppm TWA
800 ppm STEL
Maleic anhydride0.25 ppm TWA0.0025 ppm TWA
Manganese fume, dust and compounds (as Mn)Dust and compounds: 1 mg/m³ TWA
Fume: 1 mg/m³ TWA; 3 mg/m³ STEL
Inhalable: 0.1 mg/m³ TWA
Respirable: 0.02 mg/m³ TWA
Phthalic anhydride1 ppm TWA0.0003 ppm TWA
Portland cementDust: 10 mg/m³ TWARespirable dust: 1 mg/m³ TWA
Sodium tetraborates (borax)Anhydrous: 1 mg/m³ TWA
Decahydrate: 5 mg/m³ TWA
Pentahydrate: 1 mg/m³ TWA
0.75 mg/m³ TWA
Combined listing for the stated forms

TWA: eight-hour time-weighted average. STEL: 15-minute short-term exposure limit. Peak: assessed over the shortest practicable analytical period, no longer than 15 minutes. Official definitions.

These are selected values, not a complete exposure register. Check chemical identity, sampling fraction and all notations in the official lists. For WA, WorkSafe also identifies a separate phosphine implementation extension to 1 December 2029. WA requirements and exceptions.

Gas and particle detection

Different hazards require different monitoring and sampling methods.

Dustlight personal dust monitoring

Provides real-time feedback on fine dust levels using a display and colour indicators. This is indicative monitoring: it does not identify the dust’s chemical composition or replace formal occupational exposure measurement.

Enquire about Dustlight with Rowe Scientific

Dustlight personal dust monitoring

Draeger Pac 8000

A reusable personal single-gas detector. Select the sensor for the target gas and confirm the required measuring range, alarm settings and application. The pictured sensor configuration is an example.

View Pac 8000 options on Rowe.com.au

Draeger Pac 8000

Gilian GilAir Plus

A personal air-sampling pump that draws air through suitable sampling media for subsequent analysis. Select the media, flow rate and analytical method for the contaminant. The pump is sampling equipment, not a direct-reading gas or dust detector.

RC: NP0054

View GilAir Plus pump on Rowe.com.au

Gilian GilAir Plus

Where exposure is uncertain, or monitoring is needed to determine health risk, obtain a suitable assessment and sampling plan. WorkSafe WA guidance on air monitoring.

Respiratory protection

Review the complete protection system against your assessed hazards.

Eliminate or minimise airborne exposure through the hierarchy of controls. Respiratory protection addresses residual risk where required; purchasing PPE alone does not establish compliance. Source: WorkSafe WA control guidance.

Disposable and half-face masks

Disposable particle masks and reusable half-face masks serve different needs. Choose the mask, size and filter arrangement for the assessed hazard. Image shows a Draeger X-plore 3000-series half-face example.

View disposable masks on Rowe.com.au

RC: NR0022

View half-face masks on Rowe.com.au

Disposable and half-face masks

Full-face protection

Full-face masks provide a facepiece option for a suitably selected respiratory protection system. Confirm the facepiece, compatible filters and required fit. Image shows a Draeger X-plore 5500 example.

RC: NR0016

View full-face mask on Rowe.com.au

Full-face protection

Powered-system headpieces

Hoods, helmets and visors are available within the Draeger X-plore 8000 system range. Confirm the approved blower, hose and headpiece combination. Image shows an X-plore 8000 hood example.

Enquire about Dustlight with Rowe Scientific

Powered-system headpieces

Range examples shown. Confirm the required model, size, filter and system configuration with Rowe Scientific.

POWERED PARTICLE PROTECTION

Draeger X-plore 8300

A compact, lightweight powered air-purifying respirator for particle hazards. A battery-powered blower supplies continuous airflow. The system offers approved headpiece, hose and carrying options.

Compact and lightweight Powered airflow Flexible system

RC: NP0122

View X-plore 8300 blower on Rowe.com.au

Draeger X-plore 8300 powered air-purifying respirator blower unit

Cartridges and filters

Understand the filter type before selecting the complete respirator system.

The table summarises general filter classifications. It does not confirm that a filter fits any particular mask or powered respirator. Select an approved combination for the contaminant, concentration and working conditions.

Classification source: Draeger filter selection guide, p. 5. Usage restrictions: manufacturer instructions.
Filter typeColour codeGeneral classification
AXBrownOrganic gases and vapours with boiling point ≤65°C.
ABrownOrganic gases and vapours with boiling point >65°C.
BGreyInorganic gases and vapours, such as chlorine, hydrogen sulphide and hydrogen cyanide. Not carbon monoxide.
EYellowSulphur dioxide, hydrogen chloride and other acidic gases.
KGreenAmmonia and organic ammonia derivatives.
COBlackCarbon monoxide; specialised filter applications.
HgRedMercury vapour.
NOBlueNitrous gases, including nitrogen monoxide.
ReactorOrangeRadioactive iodine, including radioactive methyl iodide.
PWhiteParticles.

Combination filters carry multiple colour bands; for example, particle components add white. AX, CO, Hg, NO and Reactor applications have specific use restrictions. Follow the instructions supplied with the exact filter and the approved system. Read the classification and restriction notes.

View a Draeger bayonet combination filter on Rowe.com.au

Reduce your exposure to solvents

SCAT solvent supply and waste handling for HPLC / LCMS workflows.

Review solvent supply, waste collection and vapour control together. SCAT provides caps, funnels and exhaust-filter options for these parts of the laboratory workflow. Confirm the solvent, container thread, connections and component compatibility for your application.

Safety Caps

For HPLC solvent supply, with air valves and capillary connections. Choose the cap and fittings to match the solvent container and system.

View Safety Caps on Rowe.com.au

Safety Caps

MARCO Safety Funnels

Waste-collection funnels with a hinged lid, sealing ring and removable sieve. Confirm the container thread and required funnel variant.

View MARCO funnels on Rowe.com.au

MARCO Safety Funnels

Safety Waste Caps

Waste-collection options for bottles and collection containers, with capillary or tubing connections and exhaust-filter provision as specified for the selected cap.

View Safety Waste Caps on Rowe.com.au

Safety Waste Caps

Exhaust Filters

Activated-carbon filters for vented HPLC waste vapours. Versions with change indicators are available. Select a compatible filter and follow its replacement instructions.

View exhaust filters on Rowe.com.au

Exhaust Filters

ROWE SCIENTIFIC

Discuss your workplace requirements

Tell us about your airborne contaminants, monitoring needs, respiratory protection or HPLC / LCMS solvent-handling requirements.

Contact Rowe Scientific to discuss your requirements